*** TURBOSOUND MANCHESTER Series                             ***
***       V2.3 XP RELEASE                                    ***
*** All MODULES & OVERLAYS CREATED IN LAKE CONTROLLER V8.0.2 ***
*** All MODULES ARE CONTOUR XP FORMAT                        ***
***         README                                           ***
______________________________________________________________________________________________________
LAB GRUPPEN PLM12K44/PLM20K44 & D SERIES L DSP AMPLIFIERS ONLY - LM SERIES PROCESSORS ARE NOT SUITABLE

THIS MODULE IS FOR THE BACK MS218 SPEAKER IN A 3 HIGH CARDIOID BASS CELL

>FRONT "THIS MODULE"
>FRONT "THIS MODULE"    
<BACK            

REAR AND FRONT AMOUNTS OF CABINETS MUST USE 2 FORWARD : 1 REVERSED RATIO
REVERSED CABINET IS ALWAYS AT THE BOTTOM OF THE CELL
 
MS218 CARD FRONT XP module for use with MANCHESTER SERIES ARRAY & POINT SOURCE ELEMENTS
Pre-aligned for use with MANCHESTER SERIES ARRAY & POINT SOURCE ELEMENTS

OUTPUTS:  CORRECT OUTPUT PATCHING XP Modules DO NOT REQUIRE MOM (module output mixing) 
instead they use the new MBL (multi-band limiter)

ISVPL profile should be set to Sub/LF for 18" LF 
______________________________________________________________________________________________________

EQ OVERLAYS: NOT REQUIRED
_______________________________________________________________________________________________________

Application Notes:

GAIN: all modules assume 35 dB amplifier gain
(for PLM / D series L this is already set and locked)

WARNING: Ensure correct routing before use 

WARNING: V1.1 & V2.3 MODULES ARE NOT DESIGNED TO BE USED TOGETHER IN THE SAME SYSTEM
_______________________________________________________________________________________________________      

Please read the MANCHESTER QSG and Rigging Manual prior to use 

All MODULES & OVERLAYS CREATED IN LAKE CONTROLLER V8.0.2

*** Designed by TURBOSOUND - MAR 2024 ***